Showing posts with label publication. Show all posts
Showing posts with label publication. Show all posts

29 Sept 2014

HI Subsidies and the Construction Industry!.

HI Subsidies and the Construction Industry!.

 Click Here To Visit Egypt's Directory Homepage.
Do reduced subsidies pose a threat to Egypt's Steel & Cement Sector?
- "Find out in this report from the German-Arab Chamber of Industry and Commerce".


Egypt Business Directory brings you an excerpt of GAT-magazine, the official publication of the German-Arab Chamber of Industry and Commerce. 
The file looks at the Cement and Steel Industry in Egypt in 2012, and how subsidies affect the sector as a whole.
Get the exclusive download for free!
 Click Here To Download.
Click The Image Above Or The Following Link Here To Download Whitepaper  Or View & Save Below; 

12 Dec 2013

Hi "Offshore Technology Focus Magazine!."

Hi Recommendations To View & Open Reader To Access;


Click Here Or Image Below To Access Reader of Publications Available Online To View or/& Download.


Hi Career Read Focus "Managing Productive Measures"



The Latest of The Offshore Technology Focus Magazines Including the latest available edition Issue 13 December 2013 by clicking the following link here or any of the two images below. The direct link to access the online reader & all available issues of editions published including all the previous publications of editions that are available click here for online reader link & Issues accessible to all available published editions.

Click  Any Of The Images Below To Download Issue 13 December 2013 .pdf Format File. 


 Click Image To Download The Magazine .PDF Format File

- "Going Further!"

 Click Image To Download Magazine Issue In .PDF Format

- "Offshore Technology Focus Magazine!"

30 Nov 2013

Hi Blogger Click 'Updates!.

Click here or image to visit Hi News Blog
Hi News Blog Post Publication Information & Update:

Visit The Hi News Blog November Archive & Recently Added Posts To view the November World Economy Review click here to view article link on Hi News Blog.


*Click the following link below to view the resource location of this article post. 

Hi Clients & News blog recommendation visit to the source web site of the original article & for further in-depth Middle East, Africa & the Globe in industry related information that is found on the online community Gulf Oil & News web site by clicking here or image below.



View Our Hi E Community Blog Our blogs main homepage by clicking here or image below; for interactive online informational resources on our sustainability & future of going green direction. With Over 24 industry publications in blog archive & access to informative resourceful interactive tools. 


Our Future "Hi E Community Blog"

Visit Our Other Industry Related Blog
 "Over 10 Blog Index Sections" 

Hi Smoke Lounge BlogHi Shelf
Hi Social Perspectives
Hi E Tools
Hi Fun Box
Hi Wise Products
Hi Ask An Expert

Other blogs include our main homepa Hi E Community, Hi News & Hi Clients.

Here You Will Find HVAC Industry & Related Industry Tools & Information - Resources & Post Publications Update & Maintained Regularly. Suitable For Industry professionals or online visitors with simply a developing interest. The online Community supportive of beginner to intermediate & advanced industry knowledge base.

Now is the time to leave your valued suggestions & comments or provide us with feedback on your blogging experience. 



27 Oct 2013

Hi Field Testing Brief!.

Hi Field Testing Brief!.

The purpose of a field test is to define, via testing and measurement, the actual aerodynamic performance of a fan when installed in a system. Since installations often include elbows, obstructions, swirl and sudden changes in area, obtaining accurate measurements may be difficult. Additionally, these items may have an impact upon the unit’s performance. This impact is called a system effect.



AMCA Field Test Publications AMCA Publication 203 is a general purpose guide for the measurement of fan performance. This guide is applicable to most air handling equipment installed in any system. It includes the calculation process for loss in performance due to system effects and methods for calculating test results and uncertainties. A wealth of reference material and examples of typical applications pointing out where difficulties may be encountered are included. People involved in field testing should also be familiar with AMCA’s Certified Ratings Program outlined in Publication 211 and the concept of system effect factors (SEF) defined in AMCA Publication 201, Fans and Systems.

You may be interested in viewing an article recently published on Hi Shelf discussing the Topic of Fan Performance with reference to this article & AMCA Standards & Codes which may expand on the knowledge here. Visit Hi Shelf direct publication link post by clicking here. 

Reasons for Field Tests Three main reasons for conducting a field test are:




1. General System Evaluation - A measurement of the fan and system’s performance. This test may be used as a basis for future modifications or adjustment to the system.
2. Acceptance Test - A test specified in a sales agreement to verify that the fan is achieving the specified performance.
3. Proof of Performance Test - A test in response to a complaint to demonstrate that the fan is meeting the specified performance requirement.

Performance Rating Parameters As already stated, the specific objective of a field test is to determine the aerodynamic performance of a fan when installed in a system. The operating point will occur at the intersection of the system resistance curve and the fan curve.

Operation at any other point is impossible without altering either the fan or the system. An operating point must be fully defined by obtaining test data that allows you to determine each of the following parameters:

1. Flow Rate - The fan flow rate is the volumetric flow rate corrected to the gas density at the fan inlet. The volumetric flow rate at any location in a system can be obtained by measuring the velocity pressure according to a specified grid in the plane of interest. The number and distribution of points is
stipulated in AMCA 203. The flow in that plane is calculated by converting the average velocity pressure to its equivalent velocity and multiplying by the area of the traverse plane. The flow rate obtained in the measurement plane must be referred back to the fan inlet using the ratio of densities at the measurement plane to that of the fan inlet.

2. Fan Static Pressure - The fan static pressure is the algebraic difference between the static pressure at the fan outlet and the total pressure at the fan inlet. Static pressures using a pitot tube or static pressure taps are obtained near the fan outlet and fan inlet. The total pressure at the fan inlet is a measured value that consists of the sum of the inlet velocity and static pressures.

3. Fan Speed - This is the rotating speed of the fan shaft in revolutions per minute. Typically, measurements of fan speed are obtained at the beginning and end of a test and then averaged providing there is a small difference.

4. Fan Brake Horsepower - This is the power delivered to the fan shaft and does not include any drive losses other than the fan bearings. Nearly all field installations are driven by an electric motor in conjunction with a v-belt drive or variable frequency controller. Portable analyzers are available that read volts, amps, watts and power factor into the motor. Power out of the motor must be calculated using motor efficiency values or the ratio of actual amps and volts to nameplate values when the motor is at least loaded to 90% of full load. Fan brake horsepower values for units with v-belt drives must be calculated using the v-belt drive loss graph in Appendix L of AMCA 203. Units driven by a variable frequency controller must be by-passed to obtain accurate electrical values due to sine wave distortion. These values must then be corrected by the fan laws to the actual operating speed.

5. Fan Gas Density - The fan gas density is the density of the gas being handled at the fan inlet. The inlet density is calculated using the barometric pressure, wet and dry bulb temperature and corrections for suction or pressurized inlet conditions.

Calculation and Analysis of the Results Detailed calculations are contained in AMCA 203 for obtaining test results. To compare test results with the factory-specified fan curve it is necessary to include SEF values, relevant drive losses, and speed and density corrections. The converted operating points can then be plotted on the factory- AMCA certified performance rating curve for analysis An estimate of the individual uncertainties for each test parameter must be made. These can be combined to provide an
overall uncertainty in flow, pressure and power. An error rectangle is then established around the test point using plus and minus absolute values of the combined uncertainties. Assuming the procedures from AMCA 203 are followed, combined uncertainties range as follows:

Volume 2% to 10%
Pressure 2% to 8%
Horsepower 4% to 8%

Hi Summary';


Keep in mind that the factory tests are conducted in ideal conditions. Because fans are rarely installed in ideal conditions, field tests are frequently performed. 



Hi Pollution Engineering Buyers Guide.

Hi Pollution Engineering Buyers Guide.
"Directory for Air, Water, Waste & Remediation Markets."

Hi Free Engineering Magazines and Downloads

Hi Free Industrial & Manufacturing Magazines and Downloads.

Hi Graduate Opinion Poll.

Hi Graduate Opinion Poll.
Hi - "Engineering Field."

Hi Translate

Hi 3D SketchUp "The Easiest Way To Draw 3D"

Hi 3D SketchUp "The Easiest Way To Draw 3D"
Hi Drawing “ Dust collectors” & “Systems”.